![Iteris VersiCam User Manual Download Page 22](http://html.mh-extra.com/html/iteris/versicam/versicam_user-manual_2095535022.webp)
User Guide
22
Insert the ground lug connector bottom on the opposite side that you cut the slit in the cable sheath. The lug
should be inserted between the core wrap and copper corrugated shield.
Install a ground wire, 14 gauge or larger, to to the post on the grounding lug and then place the connector
top over the the post and secure it in place using one of the nuts provided. Run the ground wire the shortest
distance, without severe bends, to the cabinet equipment grounding buss.
Inserting Connector Bottom (Tap) Finished Grounding Lug Assembly
ICC Module Wire Terminations
You will require three 19 gauge stranded wire pairs. After the grounding lug has been installed, separate the
three wire pairs and strip each of the wires insulation back approximately 1/4 inch.
ICC Module Connector Plug
Connection
Function
Color
SDIO -
Communications
White
SDIO +
Communications
Orange
Video -
Video
White
Video +
Video
Green
GND
Power
White
VS +
Power
Blue
Summary of Contents for VersiCam
Page 1: ...Part Number 493432201 Rev F ...
Page 13: ...User Guide 13 2 1 Menu Tree ...
Page 30: ...User Guide 30 ...
Page 77: ...User Guide 77 10 TECHNICAL INFORMATION IMSA 39 2 40 2 Cable ...
Page 79: ...User Guide 79 VersiCam Specification Sheet ...
Page 80: ...User Guide 80 Phase Information ...
Page 81: ...User Guide 81 Detector Rack Configurations ...
Page 83: ...User Guide 83 ...
Page 84: ...1700 Carnegie Avenue Santa Ana CA 92705 Phone 949 270 9400 Fax 949 270 9401 ...