Operation Manual
IRZ-500 Variable Speed Drive
Руководство по эксплуатации
Станция управления ИРЗ-500
94
ANNEX B
IRZ-500 MENU STRUCTURE AND PARAMETERS TABLE
Figure B.1 – IRZ-500 menu structure
INPUT VOLTAGE PARAMETERS
N ominal voltage
Time to autorestart by voltage
N umber of autorestarts by voltage
H igh voltage
Low voltage
Voltages imbalance
Voltage correction factor
Set defaults for voltage?
Motor nominals
Overload OLP
Underload ULP
Current correction factors
Currents imbalance
Insulation resistance
Flow line pressure transducer FLPT
Phase sequence
Backspin rotation
Door blocking
Corr. factor cosf
Autorestart counters reset time
Reset autorestart counters?
Set defaults for motor protections?
Program operation
Program frequency change
Joggle (deposits removal)
Gas lock removal mode
Auto optimization of output voltage
Current limit mode
Temperature limit mode
Inverter radiato r temperature limit mode
Set frequency
Rotation direction
Motor start mode
Acceleration rate
Deceleration rate
Dynamic brake mode
U/F characteristic
Start mo de
PID-regulato r
Linear regulator
Minimum frequency
Maximum frequency
Motor type
Number of pole pairs of PMM
PMM start current
Frequency measurement units
Nominal frequency of motor
Nominal frequency of inverter
Motor roto r catch
PWM frequency
Udc change compensation
Avoiding mains voltage loss
Drive operation mo de
Set defaults for inverter?
DHS REAL-TIME
PARAMETERS
CONTROL POINTS
AND SETTINGS
REAL-TIME
PARAMETERS
DHS STATUS
*can be accessed
in case of fau lts
INVERTER FAULTS
SETTINGS OF ADDITIONAL DIGITAL INPUTS
Active status of external alarm
Protection at axternal alarm
Time to stop at ext. alarm
Ext. alarm protec.activation delay after start
Type of restart for ext. alarm
Restart delay at external alarm
Number of restarts at external alarm
Additional alarms
Field ID No.
Pad ID No.
Well ID. No.
Motor nominal power
Motor nominal supply voltage
ESP capacity
ESP nom. head
ESP max. head
Wellhead pressure
Running depth
Formation fluid density
Step-up transformer nominal power
Po wer line No.
Statistics counters
Drive equipment information
SETTINGS OF ADDITIONAL ANALOG INPUTS
Type of input signal
Settings of analog input 1
Settings of analog input 2, 3, 4
Set defaults of analog inputs?
Consumed energy
Electric meter settings
Archive writing settings
Drive network settings
Remote start in manual mode
Step-up transformer sec. voltage calculation
ESP intake pressure
Motor oil pressure
Motor oil temperature
Motor winding temperature
Motor vibration
DHS communication protection
DHS protec. activation delay after start
DHS settings
Set defaults for DHS?
SMART CONTROL MODES
*Optional
Autoadaptation mode
Autoadaptation period
Avoid ing overload
Avoid ing underload
Avoid ing motor overheating
Avoid ing inverter overheating
Bottomhole automatic draining
Deposits removal
Output voltage automatic optimization
Gas lock removal
Autoadaptation settings
Inverter real-time parameters
MOTOR CONTROL POINTS
AND PROTECTION FUNCTIONS
TECHNOLOGICAL SETTINGS
AND PROTECTION FUNCTIONS
INVERTER SETTINGS
REAL-TIME PARAMETERS
"ESC"
"F2"
»
»
«
»
«
»
NOTEBOOK
POWER ENERGY
ADDITIONAL SETTINGS
PASSWORD SETTING
DATE AND TIME
EVENT ARCHIVE
DIAGNOSTICS
"ESC"
"F3"
DHS ADDITIONAL PARAMETERS
SERVICE MENU
FACTORY SETTINGS
«
«
Drive status Start/stop cause
Uab out
Ubc out
Uca out
F
Backspin
Imbal U
Imbal I
Phase seq.
Load
Motortype
Udc
Uab out
Ubc out
Uca out
Uab tranf
Ubc transf
Uca transf
Uinvert/transf
Ua
Ub
Uc
Iu
Iv
Iw
Tmicrocontr
Drive status Start/stop cause
Mod e of operation
Timer
Ia
Ib
Ic
Rinsul
Door
Uab
Ubc
Uca
CosF
Pact
Tigbt
Uinvert/transf
(or drive operation mode)
DHS CONTROL POINTS
*can be accessed
in case of fau lts
DHS status
ESP intake pressure
Motor oil pressure
Motor oil temperature
Motor wind. temperature
ESP intake temperature
Vibration - X
Vibration - Y
Vibration - Z
ESP discharge flow
Frame type
Frame
Time to autostart by voltage