A) 3 possible case
Annex 3
Tile’s alignement over the Top Flashing
Model "M-1" 60 Cells 6" Landscape
(view with local
section)
1) The bottom of the tile is tangent to the “’limite tuile” mark.
Optimal overlap and compliance with manufacturer’s instructions.
2) The tile is too long.
Trim it to align the tile’s bottom with “’limite tuile” mark.
(view with local
section)
Spot the “’limite tuile” mark on the EASY ROOF frame
3) The tile is too short.
The tile must overlap the top flashing with a minimum of 150mm.
If the « R » dimension » (distance between the marking « Limite tuile » and the tile’s
bottom) is higher than 70mm, move up the PV field. In that case the dimension « A » will
be increased, see page 13.
"R" dimension 70 mm
MAXI
Move upthe PV field