This document is the property of IRFTS. It shall not be reproduced or shared with third party without agreement IRFTS
9.1.1)
Remove the tiles of the photovoltaic field, for
L and H to see page 12 and 13
* Reference nomenclature
9.1.2)
H
L
PV field centered on the slope
This section of the manual applies only to the
installation of the PV field at the center of the slope.
For installations on the eave/gutter, go directly to
page 23 of this document
Definition of bottom flashing support batten
(side view)
Y = X - 8 mm MINI
1) Define the thickness of the bottom flashing batten according to the thickness of the support batten
(d)*.
Reference Support
batten (d)*
(f)
(k)
X
Y
X: thickness of (d)
Y: thickness of (k)
(f)
2
°
) Position the batten (F) in order to have the top of the bottom flashing batten (H) flush with the
water flow of the tile, eventually slightly higher (a few millimeters).
(k)
20
The bottom flashing batten (K) must have a
thickness 8 mm lower than those of the
support batten (d).
Installation Instructions for the Easy-Roof System
9)
Model "M-1" 60 Cells 6" Landscape