The battens must pass under the frame, to exceed this one of at least 200 mm MINI outside the PV field.
For a roof without tiles battens, it is imperatively necessary to add a horizontal batten with a thickness
identical to the support batten (d)* by line of frame, centered on the height of each line, over all the width
of the PV field.
9.3.2)
* Reference nomenclature
Flooring for the assembly of the PV field
(view with fictious frames without the tiles batten)
(Left side of PV field)
(Right side of PV field)
Battens
to add
Battens
to add
200 mm MINI
Reference support
batten
(view without the tiles batten)
If necessary according to the
recommendations, position and screw the
battens all over the width of the PV field
at 260mm from the reference support
batten (d), then at 365mm ± 100mm
from the other support batten.
260 ±100 mm
365 ±100mm
885 mm
31
Flooring
i
nstallation
Modèle “M-1” 60 Cellules 6" Paysage
365 ±100mm