P07.19
Rated voltage of
VFD
50
–1200V
/
●
P07.20
Rated current of
VFD
0.1
–6000.0A
/
●
P07.21 Factory barcode 1 0x0000
–0xFFFF
/
●
P07.22 Factory barcode 2 0x0000
–0xFFFF
/
●
P07.23 Factory barcode 3 0x0000
–0xFFFF
/
●
P07.24 Factory barcode 4 0x0000
–0xFFFF
/
●
P07.25 Factory barcode 5 0x0000
–0xFFFF
/
●
P07.26 Factory barcode 6 0x0000
–0xFFFF
/
●
P07.27
Type of present
fault
0: No fault
1: Inverter unit U phase protection (OUt1)
2: Inverter unit V phase protection (OUt2)
3: Inverter unit W phase protection (OUt3)
4: Overcurrent during acceleration (OC1)
5: Overcurrent during deceleration (OC2)
6: Overcurrent during constant speed (OC3)
7: Overvoltage during acceleration (OV1)
8: Overvoltage during deceleration (OV2)
9: Overvoltage during constant speed (OV3)
10: Bus undervoltage fault (UV)
11: Motor overload (OL1)
12: VFD overload (OL2)
13: Phase loss on input side (SPI)
14: Phase loss on output side (SPO)
15: Rectifier module overheat (OH1)
16: Inverter module overheat (OH2)
/
●
P07.28
Type of the last
fault
/
●
P07.29
Type of the last
but one fault
/
●
P07.30
Type of the last
but two fault
/
●
P07.31
Type of the last
but three fault
/
●
P07.32
Type of the last
but four fault
/
●