Goodrive350-19 series VFD Function parameter list
- 353 -
Function
code
Name
Description
Default
value
Modify
closing
to P90.28 with a maintenance frequency within
P90.29. When output frequency <= P90.18 (or
P90.19 in reverse running), the delay before brake
release starts. When the delay reaches P90.24 (or
P90.25 in reverse running), the VFD outputs brake
closing signal. The delay after brake release
starts. The VFD decelerates to zero and stops
within the time P90.26 (or P90.27 in reverse
running)
P90.12 , P90.13 setting range: 0.0
–200.0% (of the
motor rated current)
P90.14, P90.15 setting range: 0.0
–200.0% (of the
motor rated torque)
P90.16, P90.17, P90.18, P90.19 setting range:
0.00
–20.00Hz
P90.20, P90.21, P90.22, P90.23, P90.24, P90.25,
P90.26, P90.27 setting range: 0.000
–5.000s
Note:
If reverse-running delay is 0, the
forward-running delay is used.
P90.28 setting range: 0.00
–50.00Hz
P90.29 setting range: 0.000
–5.000s
P90.30 setting range: 0.000
–10.000s
P90.28
Maintenance
frequency for stop
5.00Hz
○
P90.29
Maintenance
frequency hold
time for stop
0.000s
○
P90.30
Torque verification
fault detection
time
3.000s
○
P90.31
Enabling the
monitoring on
brake status
P90.31 setting range: 0
–1
0: Disable
1: Enable
When the function is disabled, no brake feedback
fault is reported.
After it is enabled, brake status can be monitored.
In open-loop mode: If the actual brake status is
different from the S-terminal given brake feedback
signal during running or stop, the brake feedback
fault (FAE) is reported after the brake feedback
exception delay P90.32.
In closed-loop mode: During the stop, if a brake
feedback exception occurs, the brake feedback
fault (FAE) is reported after the brake feedback
exception delay P90.32. During running, if a brake
0
◎
P90.32
Brake feedback
exception delay
(brake feedback
detection time)
1.000s
○
P90.33
Brake monitoring
current threshold
100.0%
○
P90.34
Enabling speed
reference under
brake status error
0
◎
P90.35
Speed reference
under brake
status error
5.00Hz
○