Goodrive350-19 series VFD Troubleshooting
- 401 -
Alarm
code
Alarm type
Possible cause
Corrective measure
A-bS
Brake failure alarm
The
brake
force
is
insufficient.
The encoder is abnormal.
The zero servo detection
parameter
is
set
is
improperly.
Check whether the brake
works normally.
Check whether the encoder
works normally.
Check whether the zero servo
tolerance pulse threshold is
too small.
A-FA
Brake feedback
alarm
The brake feedback circuit
is disconnected or in poor
contact.
The
brake
feedback
detection time is too short.
Check the brake feedback
circuit.
Increase the detection time
P90.32 to a proper value.
A-SL
Loose rope
protection alarm
The hook rope is abnormal.
The downward loose rope
parameter
setting
is
improper.
Check whether the hook rope
is normal.
Check whether the downward
loose rope detection torque is
proper.
A-Ot1
PT100
overtemperature
alarm
The current environment
temperature is too high.
PT100
overtemperature
protection
setting
is
improper.
Check the current
environment temperature.
Check
whether
PT100
overtemperature
protection
point is too small.
A-Ot2
PT1000
overtemperature
alarm
The current environment
temperature is too high.
PT1000
overtemperature
alarm setting is improper.
Check the current
environment temperature.
Check
whether
PT1000
overtemperature
protection
point is too small.
A-Pt1
PT100
disconnection alarm
PT100 connection circuit is
opened.
Check
PT100
connection
circuit.
A-Pt2
PT1000
disconnection alarm
PT1000 connection circuit
is opened.
Check PT1000 connection
circuit.
A-Ptc
PTC
overtemperature
alarm
The current environment
temperature is too high.
Check
the
current
environment temperature.
Note: