Goodrive350-19 series VFD Function parameter list
- 253 -
Function
code
Name
Description
Default
value
Modify
20: High-speed pulse HDIB input value
(0.00
–50.00kHz)
21: EtherCat/Profinet communication set value 1
(0
–1000)
22: Torque current (0
–Triple the motor rated
current)
23: Exciting current (0
–Triple the motor rated
current)
24: Set frequency (bipolar, 0
–Max. output
frequency)
25: Ramps reference frequency (bipolar, 0
–Max.
output frequency)
26: Running speed (bipolar; 0
–Synchronous
rotation speed corresponding to max. output
frequency)
27: EtherCat/Profinet communication set value 2
(0
–1000)
28: C_AO1 from PLC (You need to set P27.00 to
1.) (0
–1000)
29: C_AO2 from PLC (You need to set P27.00 to
1.) (0
–1000)
30: Running speed (0
–Twice the synchronous
speed of motor)
31: Output torque (Actual value, 0
–Twice motor
rated torque)
32
–47: Reserved variable
P06.17
Lower limit of AO1
output
Above function codes define the relation between
output value and analog output. When the output
value exceeds the set max./min. output range, the
upper/low limit of output will be adopted during
calculation.
0.0%
○
P06.18
Corresponding
AO1 output of
lower limit
0.00V
○