Goodrive20-EU series VFD
Function parameters
98
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
1: Enabled
LED hundreds: User-defined communication
command address
0: Disabled
1: Enabled
P14.07
User-defined
address for
running
commands
0x0000
–0xffff
0x1000
○
P14.08
User-defined
address for
frequency
setting
0x0000
–0xffff
0x2000
○
P17 Group Monitoring function
P17.00
Setting
frequency
Display current set frequency of the VFD
Range: 0.00Hz
●
P17.01
Output
frequency
Display current output frequency of the VFD
Range: 0.00Hz
●
P17.02
Ramp
reference
frequency
Display current ramp reference frequency of the
VFD
Range: 0.00Hz
●
P17.03 Output voltage
Display current output voltage of the VFD
Range: 0
– 1200V
●
P17.04 Output current
Display current output current of the VFD
Range: 0.0
– 5000.0A
●
P17.05
Motor speed
Display the rotation speed of the motor.
Range: 0
– 65535RPM
●
P17.06 Torque current
Display current torque current of the VFD
Range: 0.0
– 5000.0A
●
P17.07
Magnetized
current
Display current magnetized current of the VFD
Range: 0.0
– 5000.0A
●
P17.08
Motor power
Display current power of the motor.
Setting range: -300.0%
– 300.0%
(the rated current of the motor)
●
P17.09 Output torque
Display the current output torque of the VFD.
Range: -250.0
– 250.0%
●