Detailed Function Description
96
Function
Code
Binary Digit
Step
No.
ACC/DEC
Time 0
ACC/DEC
Time 1
ACC/DEC
Time 2
ACC/DEC
Time 3
BIT1
BIT0
8 00 01 10 11
BIT3
BIT2
9 00 01 10 11
BIT5
BIT4
10 00 01 10 11
BIT7
BIT6
11 00 01 10 11
BIT9
BIT8
12 00 01 10 11
BIT11
BIT10
13 00 01 10 11
BIT3
BIT12
14 00 01 10 11
PA.35
BIT15
BIT14
15 00 01 10 11
For example: To set the acceleration time of following table:
Step
No. 0 1 2 3 4
5
6
7
8
9
10
11
12
13
14 15
ACC/DEC
time group
0
1
2
3
2
1
3
0
3
3
2
0
0
0
2
2
The value of every bit of PA.34 and PA.35 is:
Low byte
BIT 0
BIT 1
BIT 2
BIT 3
BIT 4
BIT 5
BIT 6
BIT 7
PA.34 0 0 1 0 0 1 1 1
PA.35 1 1 1 1 0 1 0 0
High byte
BIT 8
BIT 9
BIT 10
BIT 11
BIT 12
BIT 13
BIT 14
BIT 15
PA.34 0 1 1 0 1 1 0 0
PA.35 0 0 0 0 0 1 0 1
So the value of PA.34 should be: 0X36E4, the value of PA.35 should be: 0XA02F
Function Code
Name
Description
Setting Range
Factory Setting
PA.36 Time
unit
0: Second
1: Hour
0~1 0
This parameter determines the unit of x step running time.