Detailed Function Description
41
6. DETAILED FUNCTION DESCRIPTION
6.1 P0 Group--Basic Function
Function
Code
Name
Description
Setting
Range
Factory
Setting
P0.00
Speed
control
mode
0:Sensorless vector control
1:Vector control With PG
2:V/F control
0~2 0
0: Sensorless vector control: It is widely used for the application which requires high
torque at low speed, higher speed accuracy, and quicker dynamic response, such as
machine tool, injection molding machine, centrifugal machine and wire-drawing machine,
etc.
1: Vector control with PG: Close-loop vector control can achieve high precision speed
control and torque control. Therefore it is suitable for the application requiring high
accuracy speed and torque, such as textile, paper, lifting and elevator, etc.
If vector control with PG mode is applied, it is needed to equip with PG card and to
correctly select and install the encoder.
2: V/F control: It is suitable for general purpose application such as pumps, fans etc.
Notice:
z
Inverter can drive only one motor when P0.00 is set to be 0 or 1. When P0.00
is set to be 2, inverter can drive multi motors.
z
The autotuning of motor parameters must be accomplished properly when
P0.00 is set to be 0 or 1.
z
In order to achieve better control characteristic, the parameters of speed
regulator (P3.00~P3.05) must be adjusted according to actual situation when
P0.00 is set to be 0 or 1.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P0.01
Run
command
source
0: Keypad (LED extinguished)
1: Terminal (LED flickering)
2: Communication (LED lights on)
0~2 0
The control commands of inverter include: start, stop, forward run, reverse run, jog, fault
reset and so on.
0: Keypad (LED extinguished);
Both RUN and STOP/RST key are used for running command control. If Multifunction