Operation
37
z
This function code is not modifiable parameter, such as actual detected
parameter, operation records and so on;
z
This function code is not modifiable in running status, but modifiable in stop
status.
5.2.2 Shortcut menu setting
Shortcut menu, in which parameters in common use can be programmed, provides a
quick way to view and modify function parameters. In the shortcut menu, a parameter
being displayed as “hP0.11” means the function parameter P0.11. Modifying parameters
in the shortcut menu has the same effect as doing at normal programming status.
Maximum 16 function parameters can be saved into the shortcut menu, and these
parameters can be added or deleted when P7.03 is set to be 0.
5.2.3 Shortcut menu operation
Shortcut menu has two levels of menus, which are corresponding to the second-level
and the third-level menus of general menu, and has no corresponding with first-level
menu.
Remarks:
In stop or running status, press QUICK/JOG to enter the shortcut first-level menu, use
UP/DOWN to select different shortcut parameter, and then press DATA/ENT to enter the
shortcut second-level menu. The method to modify parameter at the shortcut
second-level menu is the same as that at the general third-level menu. If want to return
to last display, press QUICK/JOG.
The operation example is as following:
Figure 5.3 Shortcut menu operation.