U-MATCH AIR CONDITIONERS MAINTENANCE
119
3. Disassembly of 4-way
valve
Heat connection pipes for
4 pipes of 4-way valve
with gas welding before
removal of 4-way valve.
Record the direciton of the
4-way valve and
installation postition of
each pipe before welding
away 4-way valve.
4. Removal of 4-way valve
Remove the old 4-way
valve from the pipe line.
5. Assembly of new 4-way
valve
Position accurately the
new 4-way valve.
Connect new 4-way valve
with pipe line.
Wrap the valve with wet
cloth when welding 4-way
valve in case sliding block
inside the valve should be
burnt and water flow into
the pipe line.
Welding with nitrogen and
the nitrogen pressure shall
be 0.5±0.1kgf/c
(relative
pressure).
6. Assembly of solenoid
valve
Assemble solenoid valve
onto the new 4-way valve in
order of disassembly.
7. Examination of System
and cooling medium
Pump vacuum and fill
cooling medium if the
Disassemble
connecting
pipes at E,S,D
and C orifices
Mount a new
4-way vlave
Mount
solenoid
valve
Summary of Contents for u-match on/off
Page 1: ......
Page 4: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 1 PRODUCT...
Page 24: ...U MATCH AIR CONDITIONERS PRODUCT 21 5 PIPING DIAGRAM...
Page 25: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 22 CONTROL...
Page 26: ...U MATCH AIR CONDITIONERS CONTROL 23 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation...
Page 27: ...U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation...
Page 45: ...U MATCH AIR CONDITIONERS CONTROL 42 5 2 4 Dimensions...
Page 48: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 45 INSTALLATION...
Page 91: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 88 MAINTENANCE...
Page 101: ...U MATCH AIR CONDITIONERS MAINTENANCE 98 Malfunction display E6 Communications Failure...
Page 115: ...U MATCH AIR CONDITIONERS MAINTENANCE 112...
Page 163: ......