![INVENTOR u-match on/off Service Manual Download Page 105](http://html1.mh-extra.com/html/inventor/u-match-on-off/u-match-on-off_service-manual_2084115105.webp)
U-MATCH AIR CONDITIONERS MAINTENANCE
102
Malfunction display: F5 Failure of Indoor Room Sensor at Wire Controller
Failure of Indoor Room Sensor at
Wire Controller
Remove the temperature sensor to check if
the resistance value is ok
˛
Check if the plug of the temperature sensor
is correctly connected with socket on the
main board
˛
Yes
replace the main board of the
outdoor unit
No
No
replace the temperature
sensor
check the directions of the
plug and the socket
Yes