Chapter 3: Connecting to the Line
5536 PRI RAS Communications Controller Users Guide
31
T1/PRI Cabling Requirements
The cable between the board and the carrier or the CSU must
meet the following standard T1 attenuation and transmission
requirements:
•
100 Ohms
•
Two twisted pairs, category 3 or higher
•
Maximum length: 655 feet (200 m) without a CSU, or
6200 feet (1800 meters) with a CSU
Measure and record the actual cable length between the board
and the carrier or the CSU. You will need this information
when you configure the line profile parameters.
The cable must include an RJ48C plug at the end dedicated to
the WAN board. It must also provide the appropriate plug or
cabling system at the end connected to the carrier or CSU. See
documentation for more information.
T1 Link Requirements
If the board connects to the T1/PRI line, the board and CSU
must be configured with several common parameters to
interoperate. The board’s T1 parameters are set as follows:
• Line
coding:
B8ZS
• Frame
format:
ESF (Extended Super Frame)
• Line I/O impedance:
100 Ohm
±
5%
Summary of Contents for ENTIA 5536 DM PRI
Page 34: ...Minimum System Requirements 14 Interphase Corporation...
Page 46: ...Connecting to an MVIP Bus 26 Interphase Corporation...
Page 56: ...Connecting to the Network 36 Interphase Corporation...
Page 90: ...Removing the Drivers 70 Interphase Corporation...
Page 136: ...Verifying COM Ports 116 Interphase Corporation...
Page 172: ...Saving and Editing Frames 152 Interphase Corporation...
Page 182: ...Understanding LoopTest Messages 162 Interphase Corporation...
Page 190: ...Setting Port and Clock Modes 170 Interphase Corporation...
Page 196: ...Interpreting Line Status Indicators 176 Interphase Corporation...
Page 208: ...Procedures 188 Interphase Corporation...
Page 220: ...Europe 200 Interphase Corporation...