Chapter 8: Troubleshooting
5536 PRI RAS Communications Controller Users Guide
119
In their operational state, the LEDs are as follows:
The following table describes the board status when the
sequence of LEDs appears as follows:
4
Red
Loss Of Signal (LOS), indicating no electrical power is
detected on the line.
LED
Color
State must be...
1
Green
On
2
Green
On
3
Yellow
Off
4
Red
Off
LED1
LED2
LED3
LED4
Meaning
On
On
Off
Off
Board is operational.
On
On
On
Off
A synchronization problem occurred on
the ISDN carrier side.
Off
Off
Off
On
No power is detected on the line. Make
sure cable is plugged in correctly.
Off
Off
On
Off
Your ISDN provider is sending an AIS
alarm to the board.
LED
Color
Meaning if the LED is ON...
Summary of Contents for ENTIA 5536 DM PRI
Page 34: ...Minimum System Requirements 14 Interphase Corporation...
Page 46: ...Connecting to an MVIP Bus 26 Interphase Corporation...
Page 56: ...Connecting to the Network 36 Interphase Corporation...
Page 90: ...Removing the Drivers 70 Interphase Corporation...
Page 136: ...Verifying COM Ports 116 Interphase Corporation...
Page 172: ...Saving and Editing Frames 152 Interphase Corporation...
Page 182: ...Understanding LoopTest Messages 162 Interphase Corporation...
Page 190: ...Setting Port and Clock Modes 170 Interphase Corporation...
Page 196: ...Interpreting Line Status Indicators 176 Interphase Corporation...
Page 208: ...Procedures 188 Interphase Corporation...
Page 220: ...Europe 200 Interphase Corporation...