Replacing Parts in the 1555
2-17
2
To replace the digital board
1. Install the 25-pin flex cable in the connector on the underside of the new digital
board. The contacts must face away from the digital board. Be sure the flex cable is
seated correctly and latch the connector.
2. Tilt the digital board down into position over the RF board assembly and slide the
end of the digital board into the holders on the shield. The edge of the digital board
should be flush with the shield.
Holders
Shield
2.4 GHz version
shown here