39
During normal operation, if one of the power supplies fails, a continuous alarm sounds and a
warning message displays. The message tells you that the state of the power supply system is
no longer redundant. Display the Component Status menu to determine which power supply
has failed. Identify the failed unit by the power supply LED. Replace the failed power
supply to return the system to a redundant state.
Configuration Info
This option displays the cabinet type (SAF-TE) for the InterRAID-8e cabinet, and displays
information about the current RAID firmware, including product name, slot assignment,
RAM version, ROM version, and ID (in Hex format). The SAF-TE controller executes
RAM and ROM firmware code to monitor the cabinet. The following is an example display:
PROD: InterRAID-8e
SAF-TE
SLOT 1 CARD:
I/O INTERFACE
RAM REVISION:
0.xx
ROM REVISION:
1.xx
ID: 64363264h
POST Results
This option displays the diagnostics performed during the startup power-on self-test (POST).
If an error occurs it displays in the ICP, LEDs blink, and the alarm sounds. The following is
an example display:
ROM CHKSUM
OK
RAM CHKSUM
OK
RAM R/W
OK
SCSI BUS 0
OK
SCSI BUS 1
OK
PROCESSOR
OK
Internal Temp
This option displays the current internal cabinet temperature using the highest indication of
two sensors. Cabinet temperature is measured within the drive bay area between drive slots
2 and 3, and between slots 7 and 8. By sensing cabinet temperature in these locations, the
system provides maximum protection. The temperature displays in both Fahrenheit and
Celsius degrees. The following is an example display:
CABINET INTERNAL
TEMPERATURE
96
°
F/36
°
C