16
InterServe 80 Systems
Connect the RAID SCSI cables to the disk array cabinet and MegaRAID controller as
follows.
To connect the cables:
1. Connect a RAID SCSI cable to the Channel 0 port on the cabinet and to the Channel 0
port on the MegaRAID controller. Repeat for the Channel 1 port. See the following
figure.
MegaRAID Controller
External Ports on the
PCI I/O Panel
Channel 1
Channel 0
NOTE
If necessary, the ports at the top of the deskside disk array cabinet can be used instead of the
lower ports.
2. Secure the cables using the thumb screws (finger tight only). Failure to secure the
cables properly can result in intermittent problems with the cabinet or the MegaRAID
controller.
3. Choose the proper power cord for the cabinet, depending on your country. See the
Power Supply Cord Selection instruction sheet included in the accessory pack.
4. Connect the power cord to the InterRAID-8e cabinet and to the facility power outlet, AC
distribution box, or uninterruptible power supply (UPS).
CAUTION
If the system does not connect to a UPS, data loss can occur if there is a power failure.