22
NOTE
If any of the listed parts are missing or damaged, call the Customer Response Center at
1-800-633-7248.
Installing the MegaRAID Controller
If the InterRAID-8e option includes a MegaRAID controller in the shipping carton, follow
the instructions in this section to install the controller into the system. Otherwise, go to
“Installing the Cabinet into a Rack.” The following table shows information about the rack-
mount systems that allow the InterRAID-8e option.
System
Primary Controller Slot
Secondary Controller Slots
TDZ-612 RAX
Not applicable
Any available PCI
RenderRAX
Not applicable
Any available PCI
InterServe 6x5R
Not applicable
Any available PCI
InterServe 8400,
InterServe 650/660
PCI Slot 4
PCI Slots 5 through 8
StudioZ RAX
Not applicable
PCI Slots 4 though 7
InterServe 8000
PCI slot 4
PCI slots 5 through 8
NOTE
The systems with “Not applicable” for primary controller slot use a fixed disk drive as the boot
drive. All installed MegaRAID controllers are treated as secondary.
The following figure shows the MegaRAID controller and Channels 0, 1, and 2.
Channel 0
(External)
Channel 1
Channel 2
Channel 0
Channel 1
(External)
NOTE
For those systems using an internal channel for the internal RAID section, you cannot use the
external channel with the same number. For example, the InterServe 8000 uses Channel 0
and Channel 1 for the internal RAID section. Therefore, external Channel 0 and Channel 1 is
not available for connection.