![Intel 2ND GENERATION CORE PROCESSOR FAMILY DESKTOP - THERMAL MECHANICAL S AND DESIGN GUIDELINES 01-2011 Specifications Download Page 76](http://html1.mh-extra.com/html/intel/2nd-generation-core-processor-family-desktop-thermal-mechanical-s-and-design-guidelines-01-2011/2nd-generation-core-processor-family-desktop-thermal-mechanical-s-and-design-guidelines-01-2011_specifications_2071524076.webp)
Sensor Based Thermal Specification Design Guidance
76
Thermal/Mechanical Specifications and Design Guidelines
, the red line represents the DTS 1.1 fan speed control implementation. At
75W the fans will be ~ 1600 RPM keeping the Tj at ~ 89C. Blue line represent DTS 1.0
with ambient sensor. The fans with DTS 1.0 will be roughly at the same speed
~ 1650 RPM resulting in Tj at ~ 88 C. The Golden line represents the fan speed control
option where fan ramps to keep the Tj at T
CONTROL
. Fan will be running full speed in this
case with overcooling to CPU to Tj of ~ 81 C. Below T
CONTROL
, the designer can set the
fan speed to minimum or as desired by other system cooling needs.
Notes:
1.
Tj is the CPU temperatuers and can be calulated from relative DTS value (PECI) and TjMax register.
Tj = DTS + TjMax(register)
8.5
System Validation
System validation should focus on ensuring the fan speed control algorithm is
responding appropriately to the DTS values and T
AMBIENT
data in the case of DTS 1.0 as
well as any other device being monitored for thermal compliance.
Since the processor thermal solution has already been validated using the TTV to the
thermal specifications at the predicted T
AMBIENT
, additional TTV based testing in the
chassis is not necessary.
Once the heatsink has been demonstrated to meet the TTV Thermal Profile, it should be
evaluated on a functional system at the boundary conditions.
Figure 8-9. Fan Response Comparison with Various Fan Speed Control Options
Summary of Contents for 2ND GENERATION CORE PROCESSOR FAMILY DESKTOP - THERMAL MECHANICAL S AND DESIGN GUIDELINES 01-2011
Page 12: ...Introduction 12 Thermal Mechanical Specifications and Design Guidelines...
Page 36: ...Independent Loading Mechanism ILM 36 Thermal Mechanical Specifications and Design Guidelines...
Page 62: ...PECI Interface 62 Thermal Mechanical Specifications and Design Guidelines...
Page 88: ...ATX Reference Thermal Solution 88 Thermal Mechanical Specifications and Design Guidelines...
Page 102: ...Boxed Processor Specifications 102 Thermal Mechanical Specifications and Design Guidelines...
Page 120: ...Mechanical Drawings 120 Thermal Mechanical Specifications and Design Guidelines...
Page 126: ...Socket Mechanical Drawings 126 Thermal Mechanical Specifications and Design Guidelines...
Page 130: ...Package Mechanical Drawings 130 Thermal Mechanical Specifications and Design Guidelines...