1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
Intel Confidential
31
100BASE-TX Differential Output Voltage (UTP)
8
100BASE-TX Differential Output
Voltage (UTP)
ANSI Section 9.1.2.2
8.1
Test Purpose
To measure the peak differential output voltage, V
OUT
, at the transmit pins of the UTP connector
(also known as the Active Output Interface or AOI).
8.2
Specification
“For UTP, the differential output voltage, V
OUT
, as defined in specification 9.1.3 and [
shall be: 950 mV
≤
V
OUT
≤
1050 mV.”
1
Figure 8-1. Waveform at Active Output Interface
2
8.3
Test Equipment
•
Oscilloscope with at least 1 GHz bandwidth
•
Differential probe with at least 1 GHz bandwidth and capacitance less than or equal to 1 pF
•
Host computer running gigconf.exe
1.
ANSI X3.263-1995, p 28.
2.
Based on ANSI X3.263-1995, p 29, figure 12.