10Base-T Peak Differential Output Voltage on TD Circuit
1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
68
Intel Confidential
17.5
Test Procedure
1. Connect the test equipment and UUT as shown in
Figure 17-1. Setup for 10BASE-T Peak Differential Output Voltage on TD Circuit
2. From the 10 BASE-T PHY Configuration Tests menu in gigconf.exe, select the Amplitude
5MHz: 1411.10.02 test.
3. Configure the oscilloscope according to the table below.
Differential Probe
w/ 1 GHz BW
Unit Under Test
(UUT)
Digitizing
Oscilloscope
Test Fixture 40-25
100 Ohm Resistive Load
RX
RJ-45
TX
Table 17-1. Scope Configuration for Peak Differential Output Voltage on TD Circuit
Scope Parameter
Setting
Horizontal Scale
10 to 50 ms/division
Vertical Scale
-3.1 V to +3.1 V (at 10 vertical divisions, use 620 mV/
division; at 8 divisions, use 775 mV/division)
Trigger Type
Pulse width: ~148 ns (lower bound); ~364 ns (upper
bound)
Trigger Level
Typically 0.5 V to 1.7 V.
Pulse Width Triggering
Triggering information is provided to give a good starting point for measurement. The
following guidelines will help the tester achieve the most stable display.
1. Set the trigger level as specified in the above table.
2. Select pulse width triggering.
3. Set the upper bound parameter to approximately 400 ns and the lower bound
parameter to approximately 125 ns.
4. Set the trigger mode to normal.
5. Increase the lower bound parameter gradually until the triggering is lost.
6. Decrease the lower bound parameter slowly in 6 ns increments until triggering
resumes.
7. Decrease the upper bound parameter until it is 6 ns to 15 ns above the lower trigger
bound parameter.