1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
Intel Confidential
73
10Base-T TD Circuit Impedance (Transmitter Return Loss)
19 10Base-T TD Circuit Impedance
(Transmitter Return Loss)
ANSI Section 1411.10.07
19.1
Test Purpose
To measure the transmitter return loss.
19.2
Specification
The return loss shall be
≥
15dB from 5 MHz to 10 MHz
19.3
Test Equipment
•
Network Analyzer
•
CAT 5 twisted pair cable (under 2 inches in length)
•
BNC cable, with 50-ohm characteristic impedance
19.4
Test Fixtures
•
Balun Test Fixture with 200 MHz or greater bandwidth (
)
•
Load Fixture for Network Analyzer calibration (
19.5
Test Procedure
1. Insert CAT 5 cable from the UUT into transmitter side of Balun fixture and connect Balun to
Network Analyzer with BNC cable as shown in
Figure 19-1. Test Setup for 10Base-T TD Circuit Impedance (Transmitter Return Loss)
Network Analyzer
~ 2 inch TPE cable
RX
Unit Under Test
(UUT)
TX
Balun
RX
TX
RX
BNC