10Base-T Transmitter Output Timing Jitter with Cable Model
1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
82
Intel Confidential
Figure 21-1. Test Setup for 10BASE-T Transmitter Output Timing Jitter with Cable Model
2. From the 10 BASE-T PHY Configuration Tests menu in gigconf.exe, select the Jitter With
Cable Model: 1411.10.12 test
3. Configure the oscilloscope according to table below.
Table 21-1. Scope Configuration for Peak Differential Output on TD Circuit
Scope Parameter
Setting
Horizontal Scale
10 ns/division
Vertical Scale
-600 mV to +600 mV (at 10 vertical divisions, this
equals 120 mV/division; at 8 divisions,
150 mV/division)
Trigger Type
Pulse width: ~220 ns (lower bound); ~320 ns (upper
bound)
Tight trigger (±10 ns of actual pulse width) is best.
Trigger Level
Typically 0.5 V to 1.7 V
Display Persistence
Infinite persistence
Pulse Width Triggering
Triggering information is provided to give a good starting point for measurement. The
following guidelines will help the tester achieve the most stable display.
1. Set the trigger level as specified in the above table.
2. Select pulse width triggering.
3. Set the upper bound parameter to approximately 400 ns and the lower bound
parameter to approximately 125 ns.
4. Set the trigger mode to normal.
5. Increase the lower bound parameter gradually until the triggering is lost.
6. Decrease the lower bound parameter slowly in 6 ns increments until triggering
resumes.
7. Decrease the upper bound parameter until it is 6 ns to 15 ns above the lower trigger
bound parameter.