1000BASE-T Peak Differential Output Voltage and Level Accuracy
1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
10
Intel Confidential
2.3
Test Equipment
•
Digitizing oscilloscope with at least 1 GHz bandwidth
•
Differential probe with 1 GHz or greater bandwidth
•
UUTu with gigconf.exe test software
2.4
Test Fixtures
•
100
Ω
UTP test load (
).
2.5
Test Procedure
1. Connect the test equipment as shown in the figure below.
2. Set the probe to divide by 10 and to full bandwidth.
3. Select the Amplitude and Level Accuracy: 40.6.1.2.1 Test from the 1000BASE-T PHY
Configuration Tests menu in gigconf.exe.
4. Measure the output voltage with a differential probe connected across the 100-ohm test load
for each channel.
5. Adjust oscilloscope to the settings for Point A as shown in the following table and figure:
Differential Probe
w/ 1 GHz BW
Unit Under Test
(UUT)
Digitizing
Oscilloscope
Test Fixture 40-25
100 Ohm Resistive Load
RX
RJ-45
TX
Table 2-1. Point A Peak Voltage
Trigger Settings
Trigger Type
Polarity
Limits
Level
Pulse width
Positive
7 ns to 9 ns
+500 mV
Scaling
Vertical Scale
Vertical Position
Horizontal Scale
150 mV / division
-3.0 division
5 ns / division
Cursors
Display Mode
Acquisition Mode
Horizontal bars
Vectors
Average on