TwinLock
Assembly Instructions
28
Version 1.12
Terminal
Description
1
Additional sabotage contact A (input)
2
Additional sabotage contact B (input)
3
Bolt system contact 1 A (input), only distribution function !
4
Bolt system contact 1 B (input), only distribution function !
5
Bolt system contact 2 A (input), only distribution function !
6
Bolt system contact 2 B (input), only distribution function !
7
Door contact 1 A (input), only distribution function !
8
Door contact 1 B (input), only distribution function !
9
BAS connection door contact (output), only distribution function !
10
BAS connection door contact (output), only distribution function !
11
BAS connection bolt system contact (output), only distribution function !
12
BAS connection bolt system contact (output), only distribution function !
13
Antitamper
loop (output), BAS connection
14
Antitamper
loop (output), BAS connection
15
ARMED
(output), BAS connection
16
UNARMED
(output), BAS connection
17
SU-COM
(output) (armed/unarmed), BAS connection
18
Door contact 2 A (input), only distribution function !
19
Door contact 2 B (input), only distribution function !
20
RS232 - GND
21
RS232 - RX (output)
22
RS232 - TX (input)
23
STATE
– COM (output)
24
STATE
– Closed (output)
25
STATE
– open (output)
26
BAS READY
(Input), BAS connection
27
GND
28
BLOCK UNARMING
(Input), EMA connection
29
GND
30
TIMEOUT
(input), interruption of the timer programs during opening
31
GND
32
CENTRAL
(input) bolt system contact
33
GND
34
ALARM
– no alarm (output), BAS connection
35
ALARM
– alarm (output), BAS connection
36
ALARM
– COM (output), BAS connection
37
ACKNOWLEDGEMENT
(Input), EMA connection
38
GND
39
RELEASE
(Input), EMA connection
40
GND
41
Supply voltage 12 VDC
42
GND
BUS A
Connection of the system bus A (TwinLock system)
BUS B
Connection of the system bus B (TwinLock system)
J1
Jumper for the configuration of the input BAS READY
J2
Jumper for the configuration of the input RELEASE
J3
Jumper for the configuration of the input BLOCK UNARMING
J4
Jumper for the configuration of the input ACKNOWLEDGEMENT
LED
Power LED (green) blinks when the alarm system is active.
REL1
Relay: State
REL2
Relay: Armed/disarmed
REL3
Relay: Alarm
J5 (JF)
Jumper: Remote release