TwinLock
Assembly Instructions
Version 1.12
11
2. Initial Operation
2.1. Overview Process Steps
A)
Installing or mounting individual components
(description see Chapter 2.2 to 2.8)
Attention: Do not connect the power supply or batteries!!!
B)
TwinAlarm wiring or hardware configuration
(description see Chapter 2.7)
TwinXT
wiring or hardware configuration
(description see Chapter 2.6)
C)
Bus cable installation
2 bus cables (bus A/B) from each system component are connected to
TwinConnect.
Attention:
During the initial installation, only 1 lock may be
connected. This lock will receive the lock number #1
and will in the future be operated as system lock. The
status of the system lock etermines the release of the
system for configuration and service.
The other locks will be logged in later when the
system is set up.
D)
Connecting the power supply
When a system is set up with the arming device TwinAlarm, the power supply
(12 VDC) must be carried out via the BAS. The connection is performed at the
TwinAlarm screw terminals.
For a reduced system without TwinAlarm, the power supply may be carried out
via TwinConnect (power supply unit 12 VDC).
Attention:
When batteries are used, no power supply unit may be
connected.