3. Technical Data
Input Unit: FlatControl
Power supply:
9 VDC
Alternatively, power supply unit 12 VDC via
TwinConnect
Alternative emergency power supply via mini DC
jack
Current consumption:
Stand-by condition:
approx. 30 µA
Input condition (display active)
approx. 55mA
Dimensions:
5.51 x 4.02 x 0.98 inches (L x W x H)
Environment:
32-122°F, 75% RH
Environment class II according to VdS
Protection class:
IP 30
Lock: TwinLock
Power supply:
9 VDC
Current consumption:
Idle state:
approx. 40µA
Motor operation
(without bolt load):
approx. 110 mA
Dimensions:
3.54 x 2.40 x 1.34 inches (L x W x H)
Environment:
32-122°F, 75% RH
Environment class II according to VdS
Protection class:
IP 30
Arming Device: TwinAlarm
Power supply:
12 VDC
Current consumption:
Idle state:
approx. 10mA
Each active output relay: approx. 20mA
Dimensions:
3.94 x 5.91 x 1.3 inches (L x W x H)
Environment:
32-122°F, 75% RH
Environment class II according to VdS
Protection class:
IP 30
Connections.
2 RJ11 connectors for the connection of the system busses A and B
Terminal connectors for the serial interface RS232 (RX, TC and GND, 1200 baud
8N1), power supply (12 VDC), distributor, inputs and outputs.