2.7.3. Main Distributor
Bolt system contacts
Two bolt system contacts may be connected to the arming device.
Bolt system contact 1 (terminals 3 and 4)
Bolt system contact 2 (terminals 5 and 6)
In this case, the arming device is only used as a distributor with the option for
resistance monitoring through an insertable resistor R6.
The connection of the BAS takes place via the terminals 11 and 12. All the contacts
are potential-free. If only one bolt system contact is required, the other input must be
short-circuited at the terminals (terminals 5 and 6 or 3 and 4).
Door contacts
Two door contacts may be connected to the arming device.
Door contact 1 (terminals 7 and 8)
Door contact 2 (terminals 18 and 19)
In this case, the arming device is only used as a distributor with the option for
resistance monitoring through an insertable resistor R7.
The connection of the BAS takes place via the terminals 9 and 10. All the contacts
are potential-free. If only one door contact is required, the other input must be short-
circuited at the terminals (terminals 7 and 8 or 18 and 19).