TwinLock
Assembly Instructions
34
Version 1.12
Input ACKNOWLEDGEMENT
The acknowledgement input is used for the acknowledgement of the arming
procedure. The connection takes place at the terminals 37 and 38. The active level
can be software-programmed and set with the jumper (J4) at the same time.
The display of the input unit will show the acknowledgement of the BAS (! BAS
armed !) together with an acoustic signal. The input must be activated at the latest 10
seconds after the arming procedure.
If the BAS does not provide a suitable acknowledgement, the input must be
permanently activated at the terminals (e.g. short-circuiting the terminals 37 and 38,
with the appropriate configuration).
Configuration of a potential-free switching contact of the BAS (factory default)
Contact closed: Acknowledgement
Contact open: No acknowledgement
Configuration of a live contact of the BAS
100k
µC
1
0
k
GND
GND
VCC
J4
EMA
Klemme 37
Klemme 38
1
2
3
100k
µC
1
0
k
VCC
GND
GND
J4
EMA
12V
0V
Klemme 38
Klemme 37
1
2
3