TwinLock
Assembly Instructions
8
Version 1.12
1.2.3. Bus distributor: TwinConnect
The bus distributor TwinConnect enables the
connection of the individual system components.
The system is connected by means of a redundant
bus system (BUS A and BUS B). This bus system
allows the entire system to be upgraded to 2/3 locks
(TwinLock 7220).
TwinConnect allows the connection of the input unit, the arming device, and up to 2/3
locks. There is also the possibility to cascade several bus distributors, i.e. to connect
several TwinConnect units in series, to be able to connect several locks.
In addition, TwinConnect has a power supply unit (12 VDC), which can supply the
TwinLock lock system. (When the arming device is connected, however, the system
must be supplied through the BAS).
1.2.4. Extension Unit: TwinXT
The TwinLock system can very easily be extended by 4
inputs and 2 outputs by means of the extension unit
TwinXT.
Basically, a TwinXT can be connected to each
lock in the system. Consequently, each lock can be
specifically locked or released, and each lock can have
a bolt system contact.
2 switching inputs (release/bolt system contact) for lock 1
2 switching inputs (release/bolt system contact) for lock 2
2 relay outputs (status/silent alarm) (30V/1A)
Power supply 12 VDC
Antitamper loop with tamper switch