TwinLock 7220: 
The default code 1 2 3 4 5 6 7 8 is pre-programmed for the user no. #00 (= 
master/system master). The user codes #01…#35 of the individual locks 
have been deactivated by the manufacturer. 
 
 
TwinLock eCode/WTU/compact: 
The  default  code  1 2 3 4 5 6   is  pre-programmed  for  the  user  no.  #00  (= 
master).  
The  default  code  1  1  1  1  1  1   is  pre-programmed  for  the 
systemcode/Managercode. 
 
The  user  codes  of  the  individual  locks  have  been  deactivated  by  the 
manufacturer. (Programming see manual) 
 

 

I) 

Sealing of TwinAlarm

 

 

The  provided  sealing  adhesive  labels  must  be  adhered  on  top  of  the 
TwinAlarm cover screws. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for TwinLock compact

Page 1: ...105361 M 102309 High Security Lock Class 3 TwinLock 7220 WTU 3 G 105133 G 102013 IAS ACE Switch Element Class C G 108062 Intrusion detector TwinAlarm G 106016 G 106015 IAS ACE Locking Element Class C G 108062 Intrusion detector TwinAlarm M 106302 M 106301 High Security Lock Class 2 TwinLock WTU I eCode compact ...

Page 2: ...ore be given for the accuracy of the contents We can neither take over a legal responsibility nor any liability for incorrect information and their consequences Suggestions for improvements and comments are gladly accepted Trademarks The use of a trademark not shown below is not an indication that it is freely available for use INSYS is a registered trademark of INSYS MICROELECTRONICS GmbH Windows...

Page 3: ...sembly and implementation of the TwinLock 7220 TwinLock eCode TwinLock WTU and TwinLock compact systems The operation and configuration of the system are described in the documents MANUAL and QUICK REFERENCE GUIDE Sections marked with this symbol contain important notes regarding the safe damage free operation of this product ...

Page 4: ...S STEPS 11 2 2 ASSEMBLY OF THE FLATCONTROL INPUT UNIT 14 2 3 ASSEMBLY OF THE TWINLOCK 17 2 4 ASSEMBLY OF THE TWINCONNECT BUS DISTRIBUTOR 19 2 5 ASSEMBLY OF THE TWINXT EXTENSION UNIT 20 2 6 ASSEMBLY OF THE ARMING DEVICE TWINALARM 26 2 7 TWINALARM WIRING AND HARDWARE CONFIGURATION 27 2 7 1 General Interfaces 29 2 7 2 Connecting the Burglary Alarm System 31 2 7 3 Main Distributor 38 2 7 4 Remote Rele...

Page 5: ...2 5 1 General 1 1 System Graphics TwinLock 7220 Alarm TwinLock TwinLock TwinLock Secured Area TwinConnect TwinLock TwinLock FlatControl BUS A BUS A BUS B BUS B BUS A BUS B VdS TwinLock TwinAlarm BUS A BUS B Zeitsperre inaktiv RS232 VdS I O BAS ...

Page 6: ...l Power supply and Twin XT 1 lock TwinLock 7220 eCode WTU compact Flat Control incl Power supply and Twin XT 2 locks 1 2 3 4 7 F 5 6 8 9 0 F TwinConnect TwinLock TwinXT BAS EMA FlatControl Power Supply 1 2 3 4 7 F 5 6 8 9 0 F TwinConnect TwinLock TwinXT TwinLock BAS EMA FlatControl Power Supply ...

Page 7: ...Lock 7220 or 1 2 Locks TwinLock eCode WTU compact 1 Arming device BAS connection distributor 1 Bus distributor Connector for the individual components hub 1 2 Extension units TwinXT 1 2 1 Input Unit FlatControl The input unit is mounted on the outside of the safe see assembly of the input unit and is used to control and operate the locking system code input programming etc as well as to arm or dis...

Page 8: ...be able to connect several locks In addition TwinConnect has a power supply unit 12 VDC which can supply the TwinLock lock system When the arming device is connected however the system must be supplied through the BAS 1 2 4 Extension Unit TwinXT The TwinLock system can very easily be extended by 4 inputs and 2 outputs by means of the extension unit TwinXT Basically a TwinXT can be connected to eac...

Page 9: ...arm system are evaluated The TwinAlarm housing is protected against sabotage by the means of a tamper switch and protection on all sides and it is secured with a sealing adhesive label BAS Inputs BAS READY Prevents the BAS from being armed customization by jumper and software DISARM BLOCK prevents the BAS from being disarmed customization by jumper and software RELEASE Prevents the unlocking of th...

Page 10: ... the screw terminals Resistors for resistance monitored lines may be employed ARMED DISARMED The Relay is used to arm or disarm the burglary alarm system All relay contacts are directed to the screw terminals Resistors for resistance monitored lines may be employed STATUS The relay is used to indicate the status of all locks in the system All relay contacts are directed to the screw terminals Resi...

Page 11: ... initial installation only 1 lock may be connected This lock will receive the lock number 1 and will in the future be operated as system lock The status of the system lock etermines the release of the system for configuration and service The other locks will be logged in later when the system is set up D Connecting the power supply When a system is set up with the arming device TwinAlarm the power...

Page 12: ...ng of the alarm control TwinAlarm TwinAlarm activation Configure the TwinAlarm input levels description see manual TwinLock 7220 The system master code has been set to 1 2 3 4 5 6 7 8 by the manufacturer TwinLock WTU The Mastercode has been set to 1 2 3 4 5 6 by the manufacturer The system managfer code has been set to 111111 by the manufacturer H Other Programming Functions In an unlocked state a...

Page 13: ...ed by the manufacturer TwinLock eCode WTU compact The default code 1 2 3 4 5 6 is pre programmed for the user no 00 master The default code 1 1 1 1 1 1 is pre programmed for the systemcode Managercode The user codes of the individual locks have been deactivated by the manufacturer Programming see manual I Sealing of TwinAlarm The provided sealing adhesive labels must be adhered on top of the TwinA...

Page 14: ...rried out in the surroundings of the electronic lock Failure to comply with the installation instructions will render the manufacturer s warranty invalid Before you start attaching the keypad FlatControl 7237 for the electronic lock TwinLock 7220 you must install 2 suspension mounts and create a cable breakthrough at the safe door according to the hole layout see figure ...

Page 15: ...to the intended jacks of the circuit board on the back of the keypad according to Fig 2 Screwing the keypad to the safe door The keypad case must be mounted to the outside of the safe door with 2 countersunk steel screws M4 to ensure a permanent firm hold of the keypad case To avoid damaging the keypad case the mounting screws may only be tightening using a maximum torque of 1 Nm ...

Page 16: ...FlatControl receives its power supply via each of the two bus cables When a voltage failure occurs an emergency current feed for the entire system is possible via a jack at the bottom of the keyboard For this an adapter cable 7237 101 0 and a 9 volt block battery alkaline type is required For the connection of the adapter cable see figure ...

Page 17: ...ions Version 1 12 17 2 3 Assembly of the TwinLock Definition of the position of the locks when mounting in a boltwork ATTENTION For security reasons mounting of the locks close to breakthroughs in the safe door is not permitted ...

Page 18: ... not be under tension or pressure The maximum bolt stress in unlocking direction is 50 N The protruding of the locking bolt may be steplessly adjusted from 9mm to 15mm Bolt hub 15mm attention the protruding of the locking boltmay be adjusted just by extended bolt When used in normal living and office environments the electronic lock is maintenance free After approximately 10 000 shuttings a securi...

Page 19: ...connecting piece between the individual components of the system The attachment takes place with a strip of Velcro which is adhered to the bottom of the TwinConnect device For stationary installation the fastening bracket is mounted to the bottom of the TwinConnect device see detail drawing Dimensions and drilling jig 100mm 60mm B A B A B A B A B A 12VDC Oberseite Unterseite Befestigungsklett Befe...

Page 20: ...onnect the TwinXT device to the according lock using the accessory cable Connect the input contacts if used Connect the output contacts if used Connect the power supply only when the output relay is used Activate the lock I O functions at the control units FlatControl Settings Lock Lock I O Yes see TwinLock 7220 manual ...

Page 21: ...1 Shared connection State 12 State Closed 13 State Open 14 Shared connection Silent alarm 15 Silent alarm Activated 16 Silent alarm Idle Lock1 Connected with TwinLock1 via the accessory cable Lock2 Connected with TwinLock2 via the accessory cable Deckelkontakt Sabotagelinie 1 12VDC GND Alarm Zustand Freigabe Schloss 1 Riegelwerk Schloss1 Schloss1 REL Zustand REL Alarm TwinLock Schloss 1 Schloss2 F...

Page 22: ...terminals 9 and 10 The supply voltage only feeds TwinXT i e not the whole lock system can be fed via TwinXT Note If only the input contacts are used no power supply is required The supply voltage is connected to the TwinConnect device via the two terminals TwinLock TwinXT TwinLock TwinConnect Externes Netzteil 12VDC 500mA stabilisiert BUS A BUS B BUS A BUS B 12V GND ...

Page 23: ...d terminals 3 and 4 Contact closed Lock blocked unlocking locking blocked terminals 3 and 4 Bolt system contact lock 1 When the bolt system contact is closed the according lock of the TwinLock system is also closed i e it will not be possible to lock the lock During a locking process the display of the control unit will show the error message Bolt system The lock can not be locked Contact open Loc...

Page 24: ...atically closing with door switch Outputs Alarm contact When during the opening of the according lock or during the input of a code an alarm code unlocking code last digit 1 see manual TwinLock 7220 is entered at the control unit a silent alarm is triggered at the output relay The contact closes for approx 1 second Contact closed Idle Terminal 14 and 16 Contact closed Silent alarm triggered durati...

Page 25: ...ditional elements to the antitamper loop If no further sabotage elements are connected the jumper next to the tamper switch is set Instead of the jumper resistance monitoring of the antitamper loop may be soldered in In idle state the antitamper loop is closed R5 Deckelkontakt Widerstandsüberwachung optional Klemme Klemme Anschluss für Sabotagelinie ...

Page 26: ...e fastened within the bolt system in a mechanically stable way The housing of the arming device has recesses to mount all inserted cables with cable ties for strain relief Furthermore TwinAlarm has a tamper switch and an area sensor on all sides for sabotage monitoring The lead sealing of the arming device takes place via 2 sealing adhesive labels which must be adhered on top of the two cover scre...

Page 27: ... as a connecting link between the TwinLock 7220 system and a burglary alarm system BAS The in bound or out bound cables are fastened at the alarm device with terminals The insertion of the cables takes place via the perforations lateral from the housing floor required cable entry points must be broken off There are additional recesses for the strain relief of the cables using cable ties in the hou...

Page 28: ...ection 18 Door contact 2 A input only distribution function 19 Door contact 2 B input only distribution function 20 RS232 GND 21 RS232 RX output 22 RS232 TX input 23 STATE COM output 24 STATE Closed output 25 STATE open output 26 BAS READY Input BAS connection 27 GND 28 BLOCK UNARMING Input EMA connection 29 GND 30 TIMEOUT input interruption of the timer programs during opening 31 GND 32 CENTRAL i...

Page 29: ...is interrupted Contact open Timer program stays active Main switch bolt system A switching contact NO switch that is connected to the terminals 32 and 33 will prevent the locking of the doors when the door is opened and the bolt system is closed Contact closed System may be locked Contact open System can not be locked Notes If no bolt system contact is used the input must be bridged Factory defaul...

Page 30: ... of an event log The entire event log or each logged event can be output immediately after it has been entered into the log buffer Interface parameters 1 200 baud Data format 8N1 No hardware handshake The interface can also be used to perform a diagnosis of the arming device for maintenance purposes Klemme 20 Klemme 21 Klemme 22 GND RX TX RS232 PC oder serieller Drucker ...

Page 31: ...o the antitamper loop If no more antitamper loops are connected the terminals 1 and 2 must be short circuited Resistance monitoring of the antitamper loop may be inserted at R5 In idle state the antitamper loop is closed Note The entire area sensor cover and housing floor has a resistance of approx 1 6 KΩ If for example terminal 1 and 2 are bridged and a bridge was inserted instead of R5 factory d...

Page 32: ... the jumper J1 at the same time When the input is activated i e closed the system can arm the BAS Configuration of a potential free switching contact of the BAS Contact closed BAS ready i e arming is possible Contact open BAS not ready i e arming is not possible Configuration of a live contact of the BAS 100k µC 10k GND GND VCC J1 EMA Klemme 26 Klemme 27 1 2 3 100k µC 10k VCC GND GND J1 EMA 12V 0V...

Page 33: ...3 at the same time When the input is activated the BAS can be disarmed Configuration of a potential free switching contact of the BAS Contact closed Disarming possible Contact open Disarming blocked Configuration of a live contact of the BAS Notes If the BAS doesn t supply a signal for DISARM BLOCK this input must be bridged 100k µC 10k GND GND VCC J3 EMA Klemme 28 Klemme 29 1 2 3 100k µC 10k VCC ...

Page 34: ...acoustic signal The input must be activated at the latest 10 seconds after the arming procedure If the BAS does not provide a suitable acknowledgement the input must be permanently activated at the terminals e g short circuiting the terminals 37 and 38 with the appropriate configuration Configuration of a potential free switching contact of the BAS factory default Contact closed Acknowledgement Co...

Page 35: ...r J2 at the same time Configuration of a potential free switching contact of the BAS factory default Contact closed Release Contact open System blocked Configuration of a live contact of the BAS Notes If no release contact is used this input must be bridged otherwise the system can not be unlocked or locked factory default bridged system released 100k µC 10k GND GND VCC J2 EMA Klemme 39 Klemme 40 ...

Page 36: ...cording sockets R1 R2 Output ARMED DISARMED This output is potential free The connection of the relay takes place at the terminals 15 16 and 17 All three relay contacts are directed to the terminals Resistors for possible resistance monitoring of the BAS may be attached R3 and R4 If no resistors are required shorting bridges must be soldered into the according sockets R3 R4 R1 R2 Klemme 34 Klemme ...

Page 37: ...s place at the terminals 23 24 and 25 All three relay contacts are directed to the terminals A resistor for possible resistance monitoring of the BAS may be attached R8 If no resistor is required a shorting bridge must be soldered into the according socket R8 R8 Klemme 25 Klemme 24 Klemme 23 Zu Offen Widerstandsüberwachung ...

Page 38: ...Door contacts Two door contacts may be connected to the arming device Door contact 1 terminals 7 and 8 Door contact 2 terminals 18 and 19 In this case the arming device is only used as a distributor with the option for resistance monitoring through an insertable resistor R7 The connection of the BAS takes place via the terminals 9 and 10 All the contacts are potential free If only one door contact...

Page 39: ...lease signal function via an input contact For the remote release the jumper J5 must be inserted and the serial interface see terminal assignment TwinAlarm must be connected to a modem Release procedure Dialup and connection establishment to the TwinLock system Identification requirement send from TwinAlarm Response Requirement Release Response OK or NOK Disconnection As soon as the system reports...

Page 40: ...stem Setup Anz DMS xx Seriennummer Gespeichert Uhrzeit aktiv Datum Uhrzeit Systemcode Code ___________ System Initialisierung Datum und Uhrzeit mit Wochentag eingeben Bedieneinheit wurde gewechselt Neues System d h neue Bedieneinheit und neue Schlösser Beide Buskabel an Schloss 1 einstecken Mit ENTER bestätigen System Setup Schloss 01 Schloss 01 ordnungsgemäß angemeldet Anzeige Schloss 02 14 Abbru...

Page 41: ... the Systemcode lock 1 with the numerlcal keys TwinLock 7220 12345678 TwinLock WTU eCode compact 111111 to approve with enter To approve with enter To approve enter Enter the system code lock 2 with the numerical keys TwinLock 7220 12345678 TwinLock WTU eCode compact 111111 break up with clear To approve with enter Enter the system code lock 1 with the numerical keys TwinLock 7220 12345678 TwinLoc...

Page 42: ...nLock 7220 12345678 default TwinLock WTU eCode compact 111111 default choice with to approve with enter Enter the Systemcode lock 2 with numerical key TwinLock 7220 12345678 default TwinLock WTU eCode compact 111111 default Enter the Systemcodes lock 1 with numerlical key TwinLock 7220 12345678 TwinLock WTU eCode compact 111111 end Locks have been installed before System setup Anz DMS 02 choice wi...

Page 43: ... consumption Idle state approx 40µA Motor operation without bolt load approx 110 mA Dimensions 3 54 x 2 40 x 1 34 inches L x W x H Environment 32 122 F 75 RH Environment class II according to VdS Protection class IP 30 Arming Device TwinAlarm Power supply 12 VDC Current consumption Idle state approx 10mA Each active output relay approx 20mA Dimensions 3 94 x 5 91 x 1 3 inches L x W x H Environment...

Page 44: ...es L x W x H Environment 32 122 F 75 RH Environment class II according to VdS Protection class IP 30 Extension Unit TwinXT Power Supply 12 VDC optional Only for output relay operation Current consumption For power supply operation 12 VDC approx 20 mA Per relay Only when the inputs are used 0 mA Dimensions 3 94 x 2 36 x 0 98 inches L x W x H Environment 32 122 F 75 RH Environment class II according...

Page 45: ...Review TwinXT FlatControl MB 1 05 01 09 04 Emergency power supply for FlatControl MB 1 06 29 06 05 Update initialization 35 user codes MB 1 07 19 04 06 Review MB 19 04 06 Layout ES 1 08 30 10 06 New Layout TwinCards ES 1 09 17 11 06 Update WTU eCode compact MB 1 10 20 11 07 Update just FlatControl ES 1 12 15 05 09 Revision MR Subject to correction Support Hotline INSYS MICROELECTRONICS GmbH Waffne...

Reviews: