Copyright Innovative Technology Ltd 2008 GA717
2 ENVIRONMENT AND POWER REQUIREMENTS
ENVIRONMENT
POWER REQUIREMENTS
Table 2
– Power Requirements
Table 3
– Interface Logic Levels
CAUTION
· If the input voltage falls below 11.5 V the BV100 may not operate correctly (will reject
notes). The front bezel lights will flash to indicate incorrect conditions.
· It is recommended that the power supply used can supply at least 2.5 amperes.
Environment
Minimum
Maximum
Temperature
+3ºC
+50ºC
Humidity
5%
95% Non condensing
Table 1
– Environmental Requirements
CAUTION:
Depending upon the environment in which it is used the BV100 may at some time
require re-calibration. Please refer to Chapter 6 for details of the re-calibration process.
Electrical Supply
Minimum
Maximum
Supply Voltage (V DC)
Absolute Limits
+11.5V +14.2V
MDB IF5 Version Supply
Voltage
+18V
+48V DC or 34V AC
MDB Hardware version
+18V
+48V DC
Supply Ripple Voltage
0 V
0.25 V @ 100 Hz
Supply Currents:
Sleep (Low Power Mode)
TBC
Standby 230mA
Validating 500mA
Peak Motor Stall
2000mA
Interface Logic Levels
Logic Low
Logic High
Inputs
0 V to + 0.5 V
+3.7 V + 12 V
Outputs with 2K2
Ω
pull up
0.6 V
Pull up voltage of host interface
Maximum Current Sink
50mA per output
BV100 Operations Manual 5
Summary of Contents for BV100
Page 30: ...Copyright Innovative Technology GA717 ...
Page 39: ...Copyright Innovative Technology GA717 BV100 FINAL ASSEMBLY DRAWING NUMBER GA705 ...
Page 40: ...Copyright Innovative Technology GA717 BV100 MAIN BODY ASSEMBLY DRAWING NUMBER GA706 ...
Page 41: ...Copyright Innovative Technology GA717 BV100 STACKER SUB ASSEMBLY DRAWING NUMBER GA707 ...
Page 42: ...Copyright Innovative Technology GA717 BV100 MODULE SUB ASSEMBLY DRAWING NUMBER GA708 ...
Page 43: ...Copyright Innovative Technology GA717 BV100 BELT DRIVE SUB ASSEMBLY DRAWING NUMBER GA709 ...
Page 44: ...Copyright Innovative Technology GA717 BV100 STACKER DRIVE SUB ASSEMBLY DRAWING NUMBER GA710 ...