4.2.3 CONFIGURATION BUTTON FUNCTIONS
The functions available via the Configuration Function Button are detailed in Table 7.
Configuration Button
Power Status
Function
Press and Hold (>2 secs)
Powered ON
Sets BV100 to Programming
Mode (SSP)
Press Once (<1 sec)
Powered ON
Enables Configuration Card
Programming
Press Twice (within half a
second)
Powered ON
Current Setting Indicator
Press and hold as power is
applied
Powered OFF/ON
Resets ccTalk key to Default
setting
Table 7
– Configuration Button Functions
BV100 Programming Mode
Press and Hold the Configuration Button for at least 2 seconds whilst the BV100 is
powered up. The Bezel LED will flash rapidly to indicate that SSP is being loaded. Once this
process has finished the BV100 will reset. The BV100 will now be in Programming Mode
(SSP) and allow connection to a PC via a DA1 or DA2 adapter or connection to a DA3.
Note: This mode can only be cancelled by re-programming with a Configuration Card or via
the Validator Manager Program. Please ensure you are aware of all the BV100 programmed
settings before entering this mode. Failure to restore the original setting will stop the
BV100 from operating in the Host machine.
Configuration Card Programming Mode
Press the Configuration Button once whilst the BV100 is powered up. If done correctly the
Bezel LED will flash every 1 second. This will allow the insertion of a Configuration Card to
change the Firmware Protocol in the BV100. (See chapter 4.4 Using BV100 Configuration
Cards for full details). This mode can be cancelled by again pressing the Configuration
Button once.
Current Setting Indicator Mode
Press the Configuration Button twice within half a second whilst the BV100 is powered up.
The BV100 Bezel LED will then perform a series of flashes to indicate the current settings
within the validator. (See Program Check Procedure, Appendix D - Configuration Cards)
Encryption Key Reset Function (ccTalk
®
)
Note: This function will only be possible if the BV100 is programmed to ccTalk
®
mode. It is
not possible to reset the key from SSP mode. Press and hold the Configuration Button whilst the
BV100 powered is off. Apply the power and keep the button pressed for several seconds. The
ccTalk Encryption key will now be restored to the default setting.
4.3 PROTOCOLS
ITL strongly recommends the use of a Serial protocol (Preferably SSP) to achieve the
highest security.
BV100 Operations Manual 10
Summary of Contents for BV100
Page 30: ...Copyright Innovative Technology GA717 ...
Page 39: ...Copyright Innovative Technology GA717 BV100 FINAL ASSEMBLY DRAWING NUMBER GA705 ...
Page 40: ...Copyright Innovative Technology GA717 BV100 MAIN BODY ASSEMBLY DRAWING NUMBER GA706 ...
Page 41: ...Copyright Innovative Technology GA717 BV100 STACKER SUB ASSEMBLY DRAWING NUMBER GA707 ...
Page 42: ...Copyright Innovative Technology GA717 BV100 MODULE SUB ASSEMBLY DRAWING NUMBER GA708 ...
Page 43: ...Copyright Innovative Technology GA717 BV100 BELT DRIVE SUB ASSEMBLY DRAWING NUMBER GA709 ...
Page 44: ...Copyright Innovative Technology GA717 BV100 STACKER DRIVE SUB ASSEMBLY DRAWING NUMBER GA710 ...