Copyright Innovative Technology GA717
Program check procedure
To check settings on a programmed unit:
1.
Power on unit
2.
Click program set button on unit twice (like double click on mouse)
3.
Monitor bezel led and check flash codes
For example
A pulse interface with 50ms high, 100ms low, 2 pulse per dollar will flash 2,5,10,2
A SSP interface will only ever flash once
A ccTalk interface with 16 bit checksum, no encryption will flash 6,1
A ccTalk interface with 8 bit checksum, no encryption will flash 6,1,2
A Binary interface will flash 8,1
Flash
count
Pulse
high
Pulse
low
Pulse
per
dollar
High
speed
Disabled
ccTalk
plain
Low
power
Binary Credit
hold
SSP
1
Pulse
2 ms/10
ms/10
value
3
flash
MDB
3
IF30
4
IF31
5
ccTalk
6 1
flash
2
flash
SIO
7
1 flash
2 flash
Parallel
8
1
flash
spare
9
NIS
10
IF32
11
1
flash
spare
12
spare
13
spare
14
BV100 Operations Manual 29
Summary of Contents for BV100
Page 30: ...Copyright Innovative Technology GA717 ...
Page 39: ...Copyright Innovative Technology GA717 BV100 FINAL ASSEMBLY DRAWING NUMBER GA705 ...
Page 40: ...Copyright Innovative Technology GA717 BV100 MAIN BODY ASSEMBLY DRAWING NUMBER GA706 ...
Page 41: ...Copyright Innovative Technology GA717 BV100 STACKER SUB ASSEMBLY DRAWING NUMBER GA707 ...
Page 42: ...Copyright Innovative Technology GA717 BV100 MODULE SUB ASSEMBLY DRAWING NUMBER GA708 ...
Page 43: ...Copyright Innovative Technology GA717 BV100 BELT DRIVE SUB ASSEMBLY DRAWING NUMBER GA709 ...
Page 44: ...Copyright Innovative Technology GA717 BV100 STACKER DRIVE SUB ASSEMBLY DRAWING NUMBER GA710 ...