40
700-398-01J X-Series User Manual Issued for version 2.8x
LCD Keypad
[*] [MASTER CODE] [*] [4] [0] [*] [TIME] [*] [#]
1.
Enter the User Program Mode as per steps 1 - 4 of section User Program Mode
2.
The LCD display reads ‘Option Menu’, ‘Add User Code’.
3.
To select menu option 40, ‘Edit Time’, press the [4] [0] keys followed by the [*] key or alternatively use
the [PANIC] or [MED] keys to scroll through the list of programmable options to option 40.
4.
Press the [*] key.
5.
The LCD display reads ‘New Time?’
6.
Enter the [TIME] that you wish to edit, followed by the [*] key. The format is HHMM.
7.
Press the [#] key to exit the User Program Mode.
18.
Edit the Date - Option 41
LED Keypad
Hold down the [*] key until the beep, then enter [MASTER CODE] [*] [4] [1] [*] [DATE] [*] [#]
1.
Enter the User Program Mode as per steps 1 to 4 in section User Program Mode.
2.
Press the [4] [1] keys followed by the [*] key to select programmable option 41.
3.
The READY and ARM LEDs flash simultaneously.
4.
Enter the [DATE] that you wish to edit.
5.
The date format is [DDMMYY].
6.
To confirm the entry press [*].
7.
Press the [OPTION NUMBER] followed by the [*] key for the next option, or the [#] key again to exit user
programming.
LCD Keypad
[*] [MASTER CODE] [*] [4] [1] [*] [DATE] [*] [#]
1.
Enter the User Program Mode as per steps 1 - 4 of section User Program Mode
2.
The LCD display reads ‘Option Menu’, ‘Add User Code’.
3.
To select menu option 41 – ‘Edit Date’, press the [4] [1] keys followed by the [*] key or alternatively use
the [PANIC] or [MED] keys to scroll through the list of programmable options to option 41.
4.
Press the [*] key.
5.
The LCD display reads ‘New Date?’
6.
Enter the [DATE] that you wish to edit, followed by the [*] key. The format is DDMMYY.
7.
Press the [#] key to exit the User Program Mode
19.
Stay Zones
Stay zones are those zones that are bypassed automatically when the system is “STAY ARMED”. Any zone that
should not trigger an alarm when violated in stay mode must be programmed as a stay zone.
Stay zones need only be programmed once. Each time the system is armed in the Stay Mode the pre-selected
stay zones will be bypassed automatically. The panel allows for 4 unique STAY PROFILES to be stored, consisting
of a pre-selected combination of STAY and BUZZ zones, to suit a specific STAY ARM requirement. STAY and
BUZZ zones can only be programmed for each profile once the particular profile has been selected. See section
20.2.
NOTE: Stay arming with the [5] key does not change the current stay profile.
However, if a partition is stay armed using Stay Profile 1, it is possible to toggle the panel directly to Stay Arm
Profile 2 by holding the [5] key for two seconds until a beep is heard.
EXAMPLE:
Stay Profile 1 – used for when the family has gone to bed, and only the bedroom zones are bypassed.
Stay Profile 2 – used for family time at home. All internal zones are bypassed; but the window, door,
and outdoor zones are armed.
Stay Profile 3 – used for during the day when there is activity. In this instance, only the perimeter will
be armed.