42
700-398-01J X-Series User Manual Issued for version 2.8x
NOTE: Buzz zones will be shown by flashing LEDs. (See Section How to Program Stay Zones). A Buzz zone
cannot be selected as a Stay Zone. The Buzz status must be cleared first.
7.
Repeat steps 4 - 6 until the all the required Stay zones are programmed/cancelled.
8.
Press the [#] key to exit the Stay zone programming mode.
NOTE:
Panic zones cannot be selected as Stay zones.
20.
Buzz Zones
Violation of a Buzz zone when Stay Armed will cause the keypad buzzer to sound for a period of 30 seconds
during which time a valid user code must be entered, if not entered during this period, the system will register
an alarm condition. This feature helps prevent unnecessary false alarms.
NOTE: If an Entry/Exit zone is programmed as a Buzz zone, violation of the Entry/Exit zone (when the panel is
Stay Armed) will cause the keypad to count down entry delay time.
How to Program a Buzz Zone
LED Keypad
Hold down the [4] key until the beep, then enter [ZONE NUMBER] [*] [#]
1.
Select the required stay profile (See section 20.1).
2.
Hold down the [4] key until the keypad buzzer sounds. The POWER LED will turn off, indicating that the
panel is in the Buzz zone programming mode.
3.
Entering a [ZONE NUMBER] will toggle the corresponding LED. For example, [2] [*] will turn LED 2 on (if
off) and off (if on). (Flashing zone LEDs indicate zones that have been set as Stay zones and cannot be
changed in this menu).
4.
Turn on the LEDs corresponding to the zones you need to be Buzz zones. The zone LEDs should now
indicate only the zones that you require to be Buzz zones.
5.
Press the [*] key to page to zones 17-32. Press [*] again, for zones 33-48…
6.
After each press of the [*] key, you can repeat steps 3-4.
7.
Once satisfied with your selection, press the [#] key to exit the Buzz zone mode.
NOTE: Fire and Panic zones cannot be set as Buzz zones.
LCD Keypad
[4] [ZONE NUMBER] [*] [#]
1.
Select the required Stay Profile. (See section Stay Zones page 28)
2.
Hold down the [4] key until the keypad buzzer sounds.
3.
The LCD display reads ‘Zone *’.
4.
Press the [ZONE NUMBER] corresponding to the zone you wish to be programmed as a Buzz zone
followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones.
5.
A [Y] next to the zone number indicates that the zone has been programmed as a Buzz zone. Flashing
text indicates a Stay zone.
6.
Press the [*] key to toggle between YES and NO.
7.
Repeat steps 4 - 6 until all the required Buzz zones are programmed/cancelled.
8.
Press the [#] key to exit the Buzz zone programming mode.
21.
Chime Zones
The chime mode allows the user to monitor nominated zones while the system is disarmed. The keypad buzzer
will sound five times when the nominated zone is violated - the siren will NOT sound and no alarm condition
will be reported.
EXAMPLE:
If you wish to know each time someone enters or exits the front door of your office, program this zone as a
chime zone. The keypad will beep each time someone opens the front door.