700-398-01J X-Series User Manual Issued for version 2.8x
25.
Maintenance Code - Advanced
The maintenance code, by default is 8888 or 888888 can be used by a user (without requiring help from an
installer) to access and program a limited number of installer locations. This may be desired by a high-level user
who requires low-level access to certain limited installer locations within the Alarm Panel.
This code is used to maintain the following locations:
Locations 17-18:
Siren Time and Delay
Locations 167-178: No Movement, Auto Arm
Locations 20-22:
Keypad Lockout and Sleep
Locations 174-176: No Movement, Alarm
Locations 25-31:
Daylight Savings
Locations 180-190: Auto Arm Times
NOTE: If you want to use the maintenance code, please contact your installer for assistance.
To enter into the maintenance menu:
[Maintenance Code][*][Location Number][*][Data][*]
[8][8][8][8][*] [1][7][*] [0][0][3][0][*]
When complete exit: [#]
Locations
L OCAT ION 17
Sir e n T ime Out P e r iod (de fault = 0200)
The siren time out period is the period of time for which the siren will sound after it has been activated.
To program the time into this location, the format is [MMSS]. The valid data range is: 00m01s – 59m59s.
[Maintenance Code] [*] [1] [7] [*] [MMSS] [*]
L OCAT ION 18
Sir e n D e lay (de fault = 0200)
This location sets the siren delay period between when an audible alarm condition is registered and the siren is
activated. The alarm condition will however be reported to the base station as soon as it occurs. Panic zones
and Fire zones will cause an immediate siren even if siren delay is programmed.
Option 7 in location 14 (Global Options) must be enabled for the siren delay to have an effect.
To program the time into this location, the format is [MMSS]. The valid data range is: 00m01s – 59m59s.
[Maintenance Code] [*] [1] [8] [*] [MMSS] [*]
L OCAT ION 20
K e ypad L oc kout Count (default = 4)
If a partition has a keypad lockout enabled, the value entered in this location determines the number of
consecutive incorrect codes to activate a keypad lockout. The keypad will remain locked for the time
programmed in location 21. Activating a Keypad Panic (or dedicated panic zone or entering a duress code) will
unlock the keypad.
Option 4 in locations 221-228 (Extended Partition Options) must be enabled for the keypad lockout count to
have an effect. The valid data range is: 2 – 16.
[Maintenance Code] [*] [2] [0] [*] [KEYPAD LOCKOUT COUNT] [*]
L OCAT ION 21
K e ypad L oc kout T ime (de fault = 0030)
The value determines the period of time for which the keypad will remain locked out if the keypad lockout
count entered in location 20 has been exceeded. After this period has elapsed, a locked keypad will return to
an unlocked state. Keypad lockout is enabled by partition; refer to locations 221-228 for extended partition
options, but this period applies to all partitions.
To program the time into this location, the format is [MMSS]. The valid data range is: 00m01s – 59m59s.
[Maintenance Code] [*] [2] [1] [*] [MMSS] [*]
L OCAT ION 22
K e ypad Sle ep De lay (de fault = 0500)
This location sets the time out period before the keypad enters sleep mode. After the delay period, if there is
no keypad activity (on any keypad) the backlighting and all other status and alarm LEDs will turn off.
The following events will bring a keypad out of sleep mode: Zone violations/restorals, Tamper
violations/restorals, or key press.
To program the time into this location, the format is [MMSS]. The valid data range is: 00m01s – 59m59s.
[Maintenance Code] [*] [2] [2] [*] [MMSS] [*]