47
700-398-01J X-Series User Manual Issued for version 2.8x
L OCAT ION 25
Month to Star t D aylig ht Saving (de fault = 0)
Select the month for Daylight Saving to commence, as per Table 17.
Table 15: Month Data
Value
Month
Value
Month
Value
Month
Value
Month
0
Disabled
4
April
7
July
10
October
1
January
5
May
8
August
11
November
2
February
6
June
9
September
12
December
3
March
[Maintenance Code] [*] [2] [5] [*] [MONTH] [*]
NOTE: If this location is disabled, then by default, locations 26 and 27 will also be disabled. This means that
even if you put values into locations 26 and 27, daylight savings will not commence.
L OCAT ION 26
D ay of W ee k to Start D aylig ht Saving (de fault = 1)
Select the day of the week for Daylight Saving to commence, as per Table 19.
Table 16: Day of Week Data
[Maintenance Code] [*] [2] [6] [*] [DAY] [*]
L OCAT ION 27
W e e k of Month to Start D aylig ht Saving (de fault = 1)
Select the week of the month for Daylight Saving to commence as per Table 20. To set the last week of each
month, set the value to 5.
Table 17: Week of Month Data
Value
Day
Value
Day
1
Week One
4
Week Four
2
Week Two
5
Last Week
3
Week Three
[Maintenance Code] [*] [2] [7] [*] [WEEK] [*]
L OCAT ION 28
Month to E nd D aylig ht Saving (de fault = 0)
Select the month as per Table 17, to end Daylight Saving.
[Maintenance Code] [*] [2] [8] [*] [MONTH] [*]
NOTE: If this location is disabled, then by default, locations 29 and 30 will also be disabled. This means that
even if you put values into locations 29 and 30, daylight savings will not start.
L OCAT ION 29
D ay of W ee k to E nd D aylig ht Saving (de fault = 1)
Select the day of the week as per Table 19, to disable Daylight Saving. The valid data range is: 1 – 7.
[Maintenance Code] [*] [2] [9] [*] [DAY] [*]
L OCAT ION 30
W e e k of Month to E nd D aylig ht Saving (de fault = 1)
Select the week of the month as per Table 20, to disable Daylight Saving. The valid data range is: 1 – 5.
[Maintenance Code] [*] [3] [0] [*] [WEEK] [*]
L OCAT ION 31
D aylight Saving T ime Offs e t (de fault = 60)
Enter the daylight saving time offset that will be in force while daylight saving is enabled. The valid data range
is: 0 – 250.
[Maintenance Code] [*] [3] [1] [*] [DAYLIGHT SAVING TIME OFFSET] [*]
Value
Day
Value
Day
Value
Day
1
Monday
5
Friday
6
Saturday
2
Tuesday
4
Thursday
7
Sunday
3
Wednesday