How to Select a Stay Profile
Quick Select Method (LCD only):
Press the [5] key simultaneously with the [STAY PROFILE NUMBER] and release
1.
Ensure that the Panel is disarmed.
2.
Press the [#] key to clear any previous entries.
3.
Press the [5] key and then simultaneously press keys [1], [2], [3], or [4] – depending on the stay profile
you want to choose – then release both keys.
4.
A beep will sound to indicate successful selection of a profile (an LCD keypad will also display the profile
number).
5.
Program STAY and BUZZ zones for the profile (see section 20.2), and/or ARM the profile (with the [5]
key).
Menu Select Method:
LED Keypad
Hold down the [MODE] key until the beep, then enter [2] [*] [PROFILE NUMBER] [*]
1.
Ensure that the Panel is disarmed.
2.
Press the [#] key to clear any previous entries.
3.
Hold [MODE] down for one second until the keypad beeps.
4.
Press the [2] key followed by the [*] key.
5.
Press [1], [2], [3] or [4] for the required profile.
6.
Press the [*] key to enter. The buzzer will give a long beep.
7.
Program STAY and BUZZ zones for the profile, or ARM the profile.
LCD Keypad
[MODE] [2] [*] [PROFILE NUMBER] [*]
1.
Hold [MODE] down for one second until the keypad beeps twice.
2.
The LCD display reads ‘Mode *’.
3.
Press the [2] key followed by the [*] key.
4.
The LCD display reads ‘P *’.
5.
Press [1], [2], [3], or [4] for the required profile, followed by the [*] key.
6.
The buzzer will give a long beep.
7.
Program STAY and BUZZ zones for the profile or ARM the profile.
How to Program Stay Zones
Hold down the [3] key until the beep, then enter [ZONE NUMBER] [*] [#]
1.
Select the required stay profile (See section 20.1).
2.
Hold down the [3] key until the keypad buzzer sounds. The POWER LED will turn off, indicating that the
panel is in the Stay zone programming mode.
3.
Entering a [ZONE NUMBER] will toggle the corresponding LED. For example, [2] [*] will turn LED 2 on (if
it was off) and off (if it was on). (Flashing zone LEDs indicate zones that have been set as Buzz zones and
therefore cannot be changed in this menu – refer to section 21.1 on how to program buzz zones.).
4.
Turn on the LEDs corresponding to the zones you need to be Stay zones. The zone LEDs should now
indicate only the zones that you require to be Stay zones.
5.
Press the [*] key to page through to see zones 17-32. If you press the [*] key again, you will view zones
33-48. And press the [*] key again to see zones 49-64.
6.
After each press of the [*] key, you can repeat steps 3-5.
7.
Once satisfied with your selection, press the [#] key to exit the Stay zone mode.
LCD Keypad
[3] [ZONE NUMBER] [*] [#]
1.
Select the required stay profile (See section 20.1)
2.
Hold down the [3] key until the keypad buzzer sounds.
3.
The LCD display read ‘Zone *.’
4.
Press the [ZONE NUMBER] corresponding to the zone you wish to be a Stay zone followed by the [*] key.
Alternatively use the [PANIC] or [MED] keys to scroll through the zones.
5.
A [Y] next to a zone number indicates that that particular zone is programmed as a stay zone.
6.
Press the [*] key to toggle between YES and NO.