once in a 30-day period and can be immediately reset.
Please contact Ingersoll Rand for guidance to remedy
excessive cycles.
Recommended Checks
Install modulation. Protect the inlet valve
piston/blowdown block from cycling constantly.
Check for blockage at the discharge/customer air
piping causing the compressor to cycle all the time.
Increase the air receiver capacity.
Verify that pressure sensors are reading correctly.
Install muffler.
Load Cycles Severe
Xe Software Logic for RS machines:
Will occur if the average load cycles calculated over
the last 30 days is a value greater than 24. Also occurs
once in a 30-day period and can be immediately reset.
Please contact Ingersoll Rand for guidance to remedy
excessive cycles.
Recommended Checks