Thermistor Resistance Chart
Temp
⁰
F
Ohms
Temp
⁰
F
Ohms
Temp
⁰
F
Ohms
32
33631
104
5241
176
1194
41
25988
113
4276
185
1014
50
20244
122
3507
194
865.2
59
15889
131
2894
203
741
68
12562
140
2400
212
636.9
77
10000
149
2001
221
549.7
86
8013
158
1677
230
476.1
95
6461
167
1412
239
413.9
*Chart not applicable for Oil Free RTD sensors (see