44
P5 Pressure Inputs
Terminal Description
R-Series
New RS-Series
1AVPT (0-15 PSIG/1.03
Bar) Inlet Vacuum
P5- 1, 2, 3
P5- 1, 2, 3
2APT (0-225 PSIG/15.51
Bar) Inter stage Air
Pressure (2-Stage)
P5- 19,20,21
P5 4,5,6
3APT (0-225 PSIG/15.51
Bar) Sump Pressure
P5 4,5,6
P5 7,8,9
4APT (0-225 PSIG/15.51
Bar) Package Discharge
Pressure
P5 7,8,9
P5 10,11,12
5CPT (0-225 PSIG/15.51
Bar) Coolant Filter In
Pressure
P5 10,11,12
P5 13,14,15
6CPT (0-225 PSIG/15.51
Bar) Coolant Filter Out
Pressure
P5 13,14,15
P5 16,17,18
7APT (0-225 PSIG/15.51
Bar) Package A/C Pressure
(Dryer Option)
P5 22,23,24
P5 19,20,21
10 APT (0-225 PSIG/15.51
Bar) Remote Sensor
(Optional)
P5 16,17,18
P5 22,23,24