64
Is the inlet filter housing sealing tight on top of the
inlet valve preventing access of dirt and debris?
Is the machine using Ingersoll Rand OEM parts and
coolant?
Ensure 3APT sump pressure and 4APT package
discharge sensors are reading 0 when the machine
is not running.
Are the remote sensor and dryer
set to “ON”. If one
is turned on the other one needs to be set to off.
Is the dryer “ON” for a TAS unit?
If the machine has a dryer, check the inline filter for
obstructions.
Change Coolant Filter
Xe Software Logic for R & RS machines:
This will occur if the compressor has been running
loaded for at least 8 seconds, coolant temperature is
greater than 120°F (48.9°C), and the coolant filter
pressure drop (5CPT - 6CPT) is greater than 25 psi
(1.72 Bar). This condition must exist for 150 seconds
before the warning is issued.
Recommended Checks