![Ingersoll-Rand Xe-145M Pocket Manual Download Page 48](http://html1.mh-extra.com/html/ingersoll-rand/xe-145m/xe-145m_pocket-manual_2059339048.webp)
47
3APT has an output signal range of 0 psi (0 Bar) at 0.5
VDC to 225 psi (15.51 Bar) at 4.5 VDC.
4APT - Package Discharge Pressure
The controller monitors package discharge pressure in
order to load or unload the compressor. 4APT is
compared with the sump pressure to calculate
separator element differential.
4APT has an output signal range of 0 psi (0 Bar) at 0.5
VDC to 225 psi (15.51 Bar) at 4.5 VDC.
5CPT
– Injected Coolant Pressure
Mounted before the coolant filter to measure the inlet
pressure coming from the sump.
5CPT has an output signal range of 0 psi (0 Bar) at 0.5
VDC to 225 psi 15.51 Bar) at 4.5 VDC.
6CPT
– Coolant Filter Out Pressure
Mounted at the discharge of the coolant filter manifold
assembly to monitor the differential pressure of the
coolant filter element. The 2 readings at 5CPT and
6CPT are used to calculate differential pressure.