8.0 GENERAL INFORMATION
N55K
N75K
N75H
N100H
General
Sound pressure level dB(A) *
75
75
75
75
Maximum ambient temperature °C (°F)
46 (115)
46 (115)
46 (115)
46 (115)
Minimum ambient temperature °C (°F)
1.7 (35)
1.7 (35)
1.7 (35)
1.7 (35)
Weight Kg (lbs)
1531 (3374)
1531 (3374)
1531 (3374)
1531 (3374)
Maximum pressure barg (psig)
10 (145)
10 (145)
10 (145)
10 (145)
Minimum pressure barg (psig)
4.5 (65)
4.5 (65)
4.5 (65)
4.5 (65)
Coolant capacity litres (US gal)
30 (8)
30 (8)
30 (8)
30 (8)
HAT switch setting °C (°F)
120 (248)
120 (248)
120 (248)
120 (248)
Performance
Flow at 7.5 Barg (m³/min)
10.11
12.94
-
-
Flow at 8.5 Barg (m³/min)
9.29
12.15
-
-
Flow at 10 Barg (m³/min)
8.49
11.50
-
-
Flow at 100 psig (cfm)
-
-
372
479
Flow at 125 psig (cfm)
-
-
328
429
Flow at 140 psig (cfm)
-
-
306
413
Air Cooling System
Cooling air flow m³/min (cfm)
241 (8500)
241 (8500)
241 (8500)
241 (8500)
Maximum ΔP in air ducts Pa (inch WG)
124 (0.5)
124 (0.5)
124 (0.5)
124 (0.5)
Compressed air outlet ΔT°C (°F)
8 (15)
8 (15)
8 (15)
8 (15)
Water Cooling System
Cooling (clean) water flow l/min (US
gallon/min) @ 10°C (50 ° F) / 32°C (90°F)
51/38
(13.5 /10)
95/46
(25 /12)
51/38
(13.5/10)
95/46
(25/12)
Maximum ΔP in air ducts Pa (inch WG)
62 (0.25)
62 (0.25)
62 (0.25)
62 (0.25)
Compressed air outlet ΔT °C (°F)
14 (25)
14 (25)
14 (25)
14 (25)
Main Power Circuit A/C (W/C) ***
Package full load current at 220V (A) **
208 (196)
-
208 (196)
-
Package full load current at 400V (A) **
110 (104)
144 (138)
-
-
Package full load current at 460V (A) **
-
-
100 (94)
131 (125)
Package full load current at 575V (A) **
-
-
82 (78)
108 (103)
Max fuse size @ 220V (A)
300
400
300
400
Max fuse size @ 400V (A)
150
200
150
200
Max fuse size @ 460V (A)
150
200
150
200
Max fuse size @ 575V (A)
125
150
125
150
Fuse type
Fast acting class J, T or semiconductor type, current limiting
interrupt rating 200, 000 Amps RMS SYM
Heater Circuit
110V Single Phase Rating (A)
4
4
4
4
230V Single Phase Rating (A)
4
4
4
4
Fuse type
General purpose
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable
size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)