IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & R190-225NE
ingersollrandproducts.com
32
EN
8.0 GENERAL INFORMATION
N132K
N160K
N200H
General
Sound pressure level dB(A) *
75
75
75
Maximum ambient temperature °C (°F)
46 (115)
46 (115)
46 (115)
Minimum ambient temperature °C (°F)
1.7 (35)
1.7 (35)
1.7 (35)
Weight Kg (lbs)
3175 (6985)
3175 (6985)
3175 (6985)
Maximum pressure barg (psig)
10 (145)
10 (145)
10 (145)
Minimum pressure barg (psig)
4.5 (65)
4.5 (65)
4.5 (65)
Coolant capacity litres (US gal)
91 (24)
91 (24)
91 (24)
HAT switch setting °C (°F)
120 (248)
120 (248)
120 (248)
Performance **
Flow at 7.5 Barg (m³/min)
23.5
28.0
-
Flow at 8.5 Barg (m³/min)
22.3
26.0
-
Flow at 10 Barg (m³/min)
21.0
25.0
-
Flow at 100 psig (cfm)
-
-
993
Flow at 125 psig (cfm)
-
-
892
Flow at 140 psig (cfm)
-
-
819
Air Cooling System
Cooling air flow m³/min (cfm)
382 (13500)
382 (13500)
382 (13500)
Maximum ΔP in air ducts Pa (inch WG)
124 (0.5)
124 (0.5)
124 (0.5)
Compressed air outlet ΔT °C (°F)
8 (15)
8 (15)
8 (15)
Water Cooling System
Cooling (clean) water flow l/min (US gallon/
min) @ 10°C (50°F) / 32°C (90°F)
110/87
(29/23)
125/106
(33/28)
125/106
(33/28)
Maximum ΔP in air ducts Pa (inch WG)
62 (0.25)
62 (0.25)
62 (0.25)
Compressed air outlet ΔT °C (°F)
14 (25)
14 (25)
14 (25)
Main Power Circuit A/C (W/C)
***
Package full load current at 400V (A) **
251 (239)
301(289)
-
Package full load current at 460V (A) **
-
-
255 (245)
Package full load current at 575V (A) **
-
-
210 (202)
Max fuse size @ 380V - 415V (A)
350
450
-
Max fuse size @ 440V - 480V (A)
-
-
350
Max fuse size @ 550V - 575V (A)
-
-
300
Fuse type
Fast acting class J, T or semiconductor type, current limiting
interrupt rating 200, 000 Amps RMS SYM
Heater Circuit
110V Single Phase Rating (A)
4
4
4
230V Single Phase Rating (A)
4
4
4
Fuse type
General purpose
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable
size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)
111213.14.59
Summary of Contents for IRN100-200H-2S
Page 101: ...111213 14 59 ...
Page 102: ...ingersollrandproducts com 2013 Ingersoll Rand 111213 14 59 ...