9.0 OPERATING INSTRUCTIONS
9.1 BASIC OPERATION
WARNING
Ensure that all protective covers/guards are in place
before attempting to start the machine.
WARNING
The compressor can operate in a pressurized
shutdown mode. If the compressor stops
automatically, the airend, separator tank and oil
system can contain high pressure air. This can be
relieved by pressing the emergency stop button
and can be verified by unscrewing the coolant
fill plug which has a vent hole through which any
residual pressure will be vented. Downstream of the
separator tank may still contain system pressure
which must also be vented.
NOTICE
The language and units of measure displayed on the
Intellisys controller will be preset before leaving the
factory. If these are required to be changed, contact
your local Ingersoll Rand Service Department,
Distributor or Air Center.
Prior to starting
Refer to diagram T5716 above.
Check that the coolant level is at least visible in the
center of the sight glass, add coolant if necessary. Refer to
maintenance procedures for setting correct level.
Ensure that the discharge air isolation valve is open.
Switch on the main electrical isolation switch. The control
panel will illuminate, indicating that the line and control
voltages are available.
The contrast of the display may be adjusted by turning
the small screw which is on the right hand side of the
controller when accessed through the starter cabinet
door.
Initial check sequence
The controller will perform an initial check sequence if the
compressor (1) receives initial power to the controller or
(2) has experienced an alarm reset. While the initial check
sequence occurs, the controller will display a “Checking
Machine” message.
During the initial check sequence, the controller will
check the control system for proper operation. During
this time, if any items are found inoperative an alarm will
occur and the unit will not start.
After completion of the initial check sequence, the
controller will then display “READY TO START’. This process
should be completed within 10 seconds.